三相,UN = 380-480V。额定功率(0.75至250kW)在额定电压400V时有效 |
ACS530-01-02A6-4 |
ACS530-01-03A3-4 |
ACS530-01-04A0-4 |
ACS530-01-05A6-4 |
ACS530-01-07A2-4 |
ACS530-01-09A4-4 |
ACS530-01-12A6-4 |
ACS530-01-017A-4 |
ACS530-01-025A-4 |
ACS530-01-033A-4 |
ACS530-01-039A-4 |
ACS530-01-046A-4 |
ACS530-01-062A-4 |
ACS530-01-073A-4 |
ACS530-01-088A-4 |
ACS530-01-106A-4 |
ACS530-01-145A-4 |
ACS530-01-169A-4 |
ACS530-01-206A-4 |
ACS530-01-246A-4 |
ACS530-01-293A-4 |
ACS530-01-363A-4 |
ACS530-01-430A-4 |
电源连接 |
电压 | 三相, UN |
功率范围 | 380 至 480 V, +10%/-15% 0.75 至 250 kW |
频率 | 50/60 Hz ±5% |
功率因数 | cosϕ = 0.98 |
效率(额定功率时) | 98% |
电机连接 |
电压 | 0 至 UN, 三相 |
频率 | 0 至 500 Hz |
电机控制 | 标量控制 |
产品标准和认证 |
CE 低压指令2014/35/EU,EN 61800-5-1: 2007 机械指令2006/42/EC,EN 61800-5-2: 2007,EN 62061:2005 + AC:2010 + A1:2013 + A2:2015,EN ISO 13849-1:2015, EN ISO 13849-2:2012和EN 60204-1:2018 EMC指令2014/30/EU,EN 61800-3: 2004 + A1: 2012 RoHS III指令2011/65/EU,EN50581: 2012, China RoHS II标准GB/T 26572 Delegated directive(EU) 2015/863,EN IEC 63000:2018 Eco指令2009/125/EC,标准EN 61800-9-2: 2017 质量保证体系ISO 9001和环境体系ISO 14001 报废电气电子设备规范(WEEE)2002/96/EC TÜV Nord认证(安全功能) |
|
|
|
|
|
|
|
|
|
|
|
|
|
EMC符合EN 61800-3: 2004 + A1: 2012标准 |
ACS530-01柜内安装壁挂式变频器标配内置C2滤波器 |
环境限制 |
环境温度 |
运输 | -40 至 +70 °C |
储存 | -40 至 +70 °C |
工作区域 | -15至+40 °C,无需降容,不允许结霜 +40至+50 °C,需要降容 |
|
冷却方式 |
空冷 | 干燥清洁的空气 |
涂层 | 增强涂层电路板 |
海拔高度 | 0-1,000 m 无需降容 1,000-4,000 m 每升高100 m需降容1% |
|
相对湿度 | 5-95%,不允许有冷凝 |
防护等级 | IP20 |
功能安全 | 安全转矩取消(STO) EN 61800-5-2: SIL 3 IEC 61508 ed2: SIL 3 IEC 62061: SIL CL 3, ISO 13849-1, -2: PL e EN 60204-1 |
|
|
|
|
污染水平 | 不允许有导电灰尘 |
存储 | IEC 60721-3-1,Class 1C2(化学气体), 1S2级(固体颗粒)* |
|
运输 | IEC 60721-3-2,Class 2C2(化学气体), 2S2级(固体颗粒)* |
|
运行 | IEC 60721-3-3,Class 3C2(化学气体), 3S2级(固体颗粒)* |
|
* C = 化学活性物质 S = 机械活性物质 |
|